Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 272: 107345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38011765

RESUMO

The worldwide trend toward the construction of high-rise buildings with high energy efficiency highlights the role of building materials as a source of indoor radon in the modern urban environment. The aim of the study is to analyze the relationship between the Ra-226 activity concentration in building materials and indoor radon concentration using the example of multi-story buildings in Ekaterinburg. Measurements of the activity concentration of natural radionuclides in building materials were carried out using a new non-destructive method. A radon survey conducted early provided the data on indoor radon concentrations in the same apartments. The obtained Ra-226 activity concentrations in building materials in high-rise buildings were found to be relatively low, ranging from 9.1 to 51 Bq/kg. The typical radon entry rate by diffusion from building materials for modern Russian multi-story buildings can be accepted as equal to 0.5 Bq/(m3∙h) per 1 Bq/kg of Ra-226 activity concentration. Ra-226 in building materials has been shown to be a primary source of indoor radon in modern high-rise buildings, where this factor can cause indoor radon concentrations above the reference level of 100 Bq/m3 at low air exchange rates. The activity concentration of Ra-226 in building materials should be considered a separate parameter for regulation within the national radiation protection systems.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento de Radiação , Rádio (Elemento) , Radônio , Radônio/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento de Radiação/métodos , Poluentes Radioativos do Ar/análise , Materiais de Construção , Federação Russa , Habitação
2.
Appl Radiat Isot ; 176: 109841, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34214913

RESUMO

OBJECTIVE: In this article, IDAC-Dose2.1 and OLINDA computer codes are compared as they are the most widely used software tools for internal dosimetry assessment at the present time. OLINDA/EXM personal computer code was created as a replacement for the widely used MIRDOSE3.1 code. IDAC-Dose2.1 was developed based on the ICRP specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. IDAC uses cumulated activities per administered activity in hours and calculates the absorbed dose and the effective dose. The program calculates the dose in the Eckerman stylized family phantoms. It is useful in standardizing and automating internal dose calculations, assessing doses in clinical trials with radiopharmaceuticals, making theoretic calculations for existing pharmaceuticals, teaching, and other purposes. METHODS: To produce such a comparison, the results of this work were compared with available published data in the literature on radiopharmaceuticals. Radiopharmaceuticals with 89Zr, 153Sm, 177Lu radionuclides are used as the basis for the comparison. 89Zr, 153Sm, 177Lu radionuclides are regarded as the future of radiopharmaceutical treatment. For 89Zr, two different labelled carriers, Zr-89_cMAb U36 and Zr-89 Panitumumab, were used on patients. RESULTS: The results show a clear difference in terms of absorbed dose of the Zr-89 radiopharmaceuticals for red bone marrow when calculated by IDAC-Dose2.1 (0.76 mGy/MBq), while the estimated absorbed dose in literature results is 0.07 mGy/MBq and 0.14 mGy/MBq when the calculation is done by OLINDA program. In the case of 177Lu-EDTMP, the absorbed dose in red bone marrow is in reasonable agreement (0.63 mGy/MBq and 0.8 mGy/MBq for IDAC-Dose2.1 and OLINDA, respectively). A significant difference was found for the absorbed dose in the bone surface, which was almost twice as high for OLINDA (2.1 mGy/MBq for IDAC-Dose2.1 and 5.4 mGy/MBq for OLINDA). In some direct cases, the calculated absorbed dose in the urinary bladder wall with OLINDA is ten times higher compared to WinAct (which was utilized to calculate the total activity in the organs and tissues) and IDAC 2.1. These results are considered key to greater accuracy in internal dose calculation.


Assuntos
Lutécio/farmacocinética , Radioisótopos/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Dosagem Radioterapêutica , Samário/farmacocinética , Zircônio/farmacocinética , Feminino , Humanos , Masculino
3.
J Environ Radioact ; 232: 106575, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33711618

RESUMO

Long-term radon time series were analyzed in 14 rooms and offices to search factors influencing indoor radon concentration in high-rise buildings. Radon entry to living rooms is determined both by diffusion from building materials and advection from adjoined low-ventilated spaces. Humans affect on seasonal and diurnal radon concentration changes in high-rise buildings by activating ventilation system. Indoor-outdoor temperature difference significantly influence on the air exchange rate under uncontrolled ventilation, which is especially important in new energy efficient buildings.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento de Radiação , Radônio , Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Habitação , Humanos , Radônio/análise
4.
Biomed Phys Eng Express ; 7(1)2020 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-35131952

RESUMO

PurposeDose coefficients from rituximab, tetulomab, cetuximab, and huA33 monoclonal antibodies labelled with the radionuclide177Lu were estimated for human organs and tumours via a theoretical simulation based on experimental results.MethodsThe real experimental results were obtained from radiopharmaceutical distribution in hairless mice. Using the Sparks and Aydogan method, the cumulated activity for humans was recalculated. The simulation was used to assess the behaviour of MAbs labelled with177Lu after injection into the human body. The average absorbed doses were calculated for the most exposed organs and tissues.ResultsThe huA33 monoclonal antibodies (MAbs) labelled with 177Lu (Lu-rituximab, Lu-tetulomab, Lu-cetuximab, and Lu-huA33), presented the maximum nuclear transformation per Bq intake for the main organs (blood, kidneys, liver, lung, and spleen, as well as for a tumour) The absorbed dose in the liver is three times lower for Lu-huA33 compared to the other drugs. In the case of cetuximab, the spleen received the lowest dose compared to the other drugs. The dependencies on absorbed dose for the alveolar, bronchioles, bone surface, heart wall, kidneys, liver, lung, lymphatic nodes, and spleen, are presented. For tumours, the absorbed dose for each drug is calculated separately for a sphere of unit volume by using the information on the injected dose.Conclusion, The ratios of the dose coefficient for the tumour to each organ, indicate that lutetium-177 can be recommended for targeted radionuclide therapy since the dose per tumour is much greater than the dose per organ.


Assuntos
Anticorpos Monoclonais , Radioisótopos , Compostos Radiofarmacêuticos , Animais , Anticorpos Monoclonais/farmacocinética , Cetuximab , Camundongos , Camundongos Nus , Compostos Radiofarmacêuticos/farmacocinética , Rituximab
5.
Appl Radiat Isot ; 156: 108981, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31740242

RESUMO

The influence of aerosol particle concentration on the activity of short-lived radon decay products (RPDs) was investigated inside a standard radon box. The 218Po:214Pb:214Bi activity ratio was determined for unattached and attached fractions of radon decay products at different aerosol concentrations. For the unattached fraction, this ratio was 1:0.31:0.06, while for the attached aerosol fraction the activity ratio was 1:1.4:0.91 at a low aerosol concentration (2000 cm-3) and with the unattached fraction fp = 0.45. In this case, there was no additional aerosol in the standard radon box and the equilibrium shift ratio for the total activity (attached and unattached) was 1:0.55:0.27 for 218Po:214Pb:214Bi. When the aerosol was injected, the unattached fraction nearly disappeared at a high aerosol concentration (80000-90000 cm-3). The equilibrium shift ratio for the total activity at a high aerosol concentration was 1:2:1.5 for 218Po:214Pb:214Bi. This ratio was the same for the attached fraction. For no more than 0.01 of the unattached fractions, this ratio was 1:0.85:0.7. Radioactive equilibrium factors and unattached fractions were also determined at different aerosol particles concentrations. A negative correlation between unattached fraction and the radioactive equilibrium factor, as well as a positive correlation coefficient between the radioactive equilibrium factor and aerosol particle concentration in a standard radon box, has been determined.

6.
Appl Radiat Isot ; 151: 1-6, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31151048

RESUMO

High levels of the unattached 212Pb fraction of the 220Rn decay products in the atmosphere of the monazite storage facility were found: f1 = 0.3-0.5 at the aerosol concentration of 20 000 cm-3 and 0.1-0.16 at aerosol concentration ∼140 000 cm-3. It is shown that the sampling of aerosols in an atmosphere with a high concentration of thoron result in the local change of the equilibrium between the attached and unattached fractions near the sampling point. As a result, the measured value of the unattached fraction of thoron decay products may differ by several orders of magnitude from the mean value of unattached fraction the in the indoor atmosphere. A local increase of the unattached fraction 212Pb can take place in the worker's breathing zone in the atmosphere with a high concentration of thoron and it should be taken into account in the assessment of the inhalation intake of the thoron decay products for workers.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Metais Terras Raras , Produtos de Decaimento de Radônio/análise
7.
Appl Radiat Isot ; 145: 95-100, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30590349

RESUMO

Information regarding the number, mass, and specific surface area distributions of aerosols is extremely important for assessments of exposure to radiation due to the intake of radioactive aerosols by inhalation. In this study, these distributions were compared with the activity size distributions for radon decay products. The experiments were conducted in a radon chamber under controlled conditions for the aerosol concentrations and with size distributions in the range from 5 nm to 10 µm. The activity size distributions of the aerosols were measured by using a diffusion battery and two types of cascade impactors. The aerosol concentrations during the experiments were in the range from 2 × 103 to 2.5 × 105 cm-3. The measurements obtained with a diffusion battery demonstrated that at the low aerosol concentration, up to 80% of activity of the radon decay products was connected with aerosol particles with an activity median thermodynamic diameter (AMTD) ~1 nm (unattached fraction). After injecting the aerosols into the experimental chamber, the activity of the unattached fraction decreased to practically zero but we observed the presence of the activity of aerosols with AMTD values ~10-20 nm. After injecting the aerosols, the distribution of the aerosol specific surface area exhibited a bimodal distribution, where the median diameter in the accumulation mode was ~120 nm and the geometric standard deviation (GSD) was 1.3. The median diameter in the coarse mode changed with time due to the deposition of aerosols on the walls of the chamber, where it decreased from 5 µm (GSD = 1.6) at 15 min after injection to 2 µm (GSD = 2.5) at 120 min after injection. The distribution of the aerosol activity measured by the cascade impactor was virtually independent of the time from the moment when the aerosols were injected. The parameters used to assess the activity distribution comprised an activity median aerodynamic diameter (AMAD) ~500-650 nm and GSD = 1.5. Comparisons of the activity distributions with the distributions for the number, mass, and specific surface area showed that the closest correspondence was with the average distribution over the specific surface, whereas there were no exact correspondences with the other distributions.

8.
Radiat Environ Biophys ; 57(4): 357-363, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30324495

RESUMO

Otoliths are the organs which fish use for hearing and keeping balance. Otoliths are the most calcified tissues in the fish body. In contrast to bones, otoliths are not affected by remodeling and, therefore, they are expected to accumulate any dose from ionizing radiation during lifetime. Therefore, EPR dosimetry with fish otoliths could be an important tool for dose reconstruction in radiobiology and radioecology. It could also provide useful information remediation actions to de-contaminate waterbodies. Consequently, in the present study, otoliths of three contaminated fish species (roach (Rutilus rutilus), pike (Esox lucius) and perch (Perca Fluviatilis)) were examined with Electron Paramagnetic Resonance (EPR) spectroscopy. The fish were caught at storage reservoirs of liquid radioactive waste from Mayak PA and from the upper reach of the Techa River, which have been contaminated with different levels of radionuclide activity concentrations. It is shown that the radiation-induced EPR signal of otolith is stable and characterized by a linear dose response. However, the slope of the calibration curve (corresponding to the radiation sensitivity of the material) is not the same for different species; this may be caused by differences in mineralization. The reconstructed doses were found to be in the range from undetectable (in fish from the upper stream of the Techa River) up to 265 Gy (in roach from the most contaminated waterbody). In parallel, otoliths were measured with ß-counter to detect 90Sr/90Y. Samples were also tested on the presence of alpha-emitters, but no alpha activity above background could be detected. However, a significant activity concentration of 90Sr was detected (from 1 × 101 to 2 × 104 Bq/g). The EPR doses measured correlated with the 90Sr activity concentration measured in the otolith samples.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica , Membrana dos Otólitos/efeitos da radiação , Radiometria/métodos
9.
Radiat Prot Dosimetry ; 181(1): 6-10, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29897581

RESUMO

Analysis includes review of 63 national and regional indoor radon surveys in kindergartens and schools. Preliminary assessment of the worldwide population weighted characteristics of radon concentration in children's institutions is: arithmetic mean = 59 and geometric mean = 36 Bq/m3. Higher indoor radon concentrations in children's institutions in comparison with the dwellings can be explained by characteristics of ventilation, attendance regime and construction features. Special protocol of measurements in the kindergartens and schools is required.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Creches , Monitoramento de Radiação , Radônio/análise , Instituições Acadêmicas , Criança , Humanos
10.
Radiat Prot Dosimetry ; 177(1-2): 125-129, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036496

RESUMO

The objective of the study was comparison of the doses received due to contamination of the Techa River with those received from the indoor radon exposure. The study was performed on the example of Muslyumovo, the village closest to Mayak nuclear complex. The accidental doses were estimated using data on radionuclide intakes and ICRP-72 dose coefficients, and Techa River Dosimetry System. Radon exposure was estimated applying results of the radon surveys in 1992 and 2015. The doses prevented by means of different protection measures were considered. The maximum reduction of population exposure could be achieved in the case of timely evacuation to uncontaminated territory together with the indoor radon prevention measures.


Assuntos
Poluentes Radioativos do Ar/análise , Reatores Nucleares , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Resíduos Radioativos/análise , Radônio/análise , Rios , Poluentes Radioativos da Água/análise , Humanos , Doses de Radiação , Federação Russa
11.
Radiat Prot Dosimetry ; 177(1-2): 49-52, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036634

RESUMO

Cascade impactors based on inertial deposition of aerosols are widely used to determine the size distribution of radioactive aerosols. However, there are situations where radioactive aerosols are represented by particles with a diameter of 1-5 nm. In this case, ultrafine aerosols can be deposited on impactor cascades by diffusion mechanism. The influence of ultrafine aerosols (1-5 nm) on the response of three different types of cascade impactors was studied. It was shown that the diffusion deposition of ultrafine aerosols can distort the response of the cascade impactor. The influence of diffusion deposition of ultrafine aerosols can be considerably removed by the use of mesh screens or diffusion battery installed before cascade impactor during the aerosol sampling.


Assuntos
Aerossóis/análise , Poluentes Ocupacionais do Ar/análise , Poluentes Radioativos do Ar/análise , Tamanho da Partícula , Plutônio/análise , Polônio/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Produtos de Decaimento de Radônio/análise , Radônio/análise , Centrais Nucleares
12.
Radiat Prot Dosimetry ; 177(1-2): 91-94, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036686

RESUMO

Obtaining of the representative sample of dwellings is a basic requirement to organization of the radon survey. Since random selection is often impossible, quasi-random approaches are used. The aim of the study is to analyze errors in radon exposure assessment that resulted from rejecting the random selection. Both the modeling and experiments were conducted. Three types of errors were observed: shifting of the mean, change of the variance and mixture of the previous two.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Contaminação Radioativa do Ar/análise , Habitação , Monitoramento de Radiação/normas , Radônio/análise , Inquéritos e Questionários
13.
Radiat Prot Dosimetry ; 177(1-2): 112-115, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036708

RESUMO

The radon survey of kindergartens has been conducted in Sverdlovskaya oblast during 2013-16. Indoor radon concentrations have been measured in 180 kindergartens in 21 villages and 10 towns. The LR-115 nuclear track detectors were placed in 560 rooms (three or four rooms per kindergarten) during 2-3 months. To obtain annual values, radon measurements were carried in the cold and warm seasons. The arithmetic and geometric means of annual indoor radon concentrations in rooms are 59 and 42 Bq/m3 respectively, GSD = 2.33. Analysis of the building factors affecting radon entry is presented. The detailed radon survey was performed in one kindergarten where exceeding of national action radon level was observed.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento de Radiação/métodos , Radônio/análise , Instituições Acadêmicas , Pré-Escolar , Feminino , Humanos , Masculino , Radiometria , Federação Russa , Estações do Ano
14.
Appl Radiat Isot ; 120: 101-105, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27984708

RESUMO

The present paper describes the prototype of a calibration standard system for radon concentrations to be used in establishing the traceability of radon concentration measurements in dwellings. Radon gas was generated with a radium-226 solid source in a certified volume as a closed system. The activity of the radon that was released in the closed system was determined from the difference between the absolute activity of the standard radium solid source and the residual radon decay products (214Bi or 214Pb). A high-purity germanium (HPGe) detector, which was calibrated using gamma reference standard sources, was used to measure the activity of a radium solid source and radon decay products (214Bi or 214Pb). The emanation factor of the 226Ra source was controlled online with the HPGe detector. Radon activity was achieved at ~1500±45Bq from the radium source at 3.95±0.2kBq under equilibrium conditions. After this activity, the radon gas was transferred into the closed system producing radon activity concentrations of 31.1±0.3kBq/m3. Systematic errors were found of less than 4% with a random error around 0.5%. The random error is generally associated with the estimation of the count rate of the measured radon progenies (214Po and 214Po for alpha measurements or 214Pb and 214Bi for gamma measurements), but systematic errors are associated with the errors introduced by the instrumentation and measurement technique. The system that was developed has a high degree of accuracy and can be recommended as a national or regional prototype standard of radon activity concentration to calibrate different working radon measurement devices.

15.
Sci Total Environ ; 541: 155-160, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26409145

RESUMO

Variance of radon concentration in dwelling atmosphere is analysed with regard to geogenic and anthropogenic influencing factors. Analysis includes review of 81 national and regional indoor radon surveys with varying sampling pattern, sample size and duration of measurements and detailed consideration of two regional surveys (Sverdlovsk oblast, Russia and Niska Banja, Serbia). The analysis of the geometric standard deviation revealed that main factors influencing the dispersion of indoor radon concentration over the territory are as follows: area of territory, sample size, characteristics of measurements technique, the radon geogenic potential, building construction characteristics and living habits. As shown for Sverdlovsk oblast and Niska Banja town the dispersion as quantified by GSD is reduced by restricting to certain levels of control factors. Application of the developed approach to characterization of the world population radon exposure is discussed.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento de Radiação/métodos , Radônio/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Habitação , Federação Russa , Sérvia
16.
Appl Radiat Isot ; 107: 109-112, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26490512

RESUMO

To calibrate measurement devices for monitoring the activity concentration of (222)Rn in air, a prototype of a calibration facility is tested using a solid (226)Ra source and a high-purity germanium (HPGe) detector. An emanation box was mounted on the detector for online gamma measurements. Inside this box, a 32.8 kBq ±3% (226)Ra standard source was placed. An AlphaGUARD control radon monitor was connected to the emanation box with a pumping air system in an open flow mode as a reference monitor. The emanation coefficient of the source was controlled online by comparing the gamma activity of (214)Bi (Eγ=609.3 keV), progeny of (226)Ra, to that of the calibration source. A standard (137)Cs source, installed within the emanation box, was used as a reference for gamma spectroscopy using the HPGe detector, with a total systematic error of 4% and a random error less than 2%. The ratio between gamma measurements and AlphaGUARD was 0.94±0.4; which is within the 9% uncertainties of AlphaGUARD calibration.

17.
J Environ Radioact ; 150: 99-103, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26313426

RESUMO

The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400,000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m(3). Average indoor radon concentration by region ranges from 12 to 207 Bq/m(3). The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m(3).


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento de Radiação , Radônio/análise , Habitação , Federação Russa
18.
Radiat Prot Dosimetry ; 164(4): 582-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25977351

RESUMO

The measurement of radon flux from soil surface is the useful tool for the assessment of radon-prone areas and monitoring of radon releases from uranium mining and milling residues. The accumulation chambers with hollow headspace and chambers with activated charcoal are the most used devices for these purposes. Systematic errors of the measurements strongly depend on the geometry of the chamber and diffusion coefficient of the radon in soil. The calibration system for the attestation of devices for radon flux measurements was constructed. The calibration measurements of accumulation chambers and chambers with activated charcoal were conducted. The good agreement between the results of 2D modelling of radon flux and measurements results was observed. It was demonstrated that reliable measurements of radon flux can be obtained by chambers with activated charcoal (equivalent volume ~75 l) or by accumulation chambers with hollow headspace of ~7-10 l and volume/surface ratio (height) of >15 cm.


Assuntos
Monitoramento de Radiação/métodos , Radônio/análise , Poluentes Radioativos do Solo/análise , Adsorção , Algoritmos , Calibragem , Carvão Vegetal , Difusão , Desenho de Equipamento , Mineração , Exposição à Radiação , Monitoramento de Radiação/instrumentação , Federação Russa , Urânio
19.
Radiat Prot Dosimetry ; 164(4): 601-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25977350

RESUMO

Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low.


Assuntos
Movimentos do Ar , Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Radiação de Fundo , Algoritmos , Arquitetura de Instituições de Saúde/normas , Arquitetura de Instituições de Saúde/tendências , Habitação/normas , Habitação/tendências , Exposição à Radiação , Monitoramento de Radiação/métodos , Radônio/análise , Federação Russa , Ventilação
20.
Radiat Prot Dosimetry ; 164(4): 587-90, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979737

RESUMO

The measurement of radon equivalent equilibrium concentration (EECRn) is very simple and quick technique for the estimation of radon progeny level in dwellings or working places. The most typical methods of EECRn measurements are alpha radiometry or alpha spectrometry. In such technique, the influence of alpha particle absorption in filters and filter effectiveness should be taken into account. In the authors' work, it is demonstrated that more precise and less complicated calibration of EECRn-measuring equipment can be conducted by the use of the gamma spectrometer as a reference measuring device. It was demonstrated that for this calibration technique systematic error does not exceed 3 %. The random error of (214)Bi activity measurements is in the range 3-6 %. In general, both these errors can be decreased. The measurements of EECRn by gamma spectrometry and improved alpha radiometry are in good agreement, but the systematic shift between average values can be observed.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Radiação de Fundo , Exposição à Radiação , Monitoramento de Radiação/normas , Produtos de Decaimento de Radônio/análise , Radônio , Espectrometria gama/métodos , Absorção de Radiação , Aerossóis , Partículas alfa , Calibragem , Exposição Ambiental , Filtração , Raios gama , Habitação , Mineração , Exposição Ocupacional , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/métodos , Padrões de Referência , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...